Product:

Ecostruxure_machine_expert

(Schneider\-Electric)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 5
Date Id Summary Products Score Patch Annotated
2020-04-22 CVE-2020-7487 A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. Ecostruxure_machine_expert, Modicon_m218_firmware, Modicon_m241_firmware, Modicon_m251_firmware, Modicon_m258_firmware, Somachine, Somachine_motion 9.8
2020-04-22 CVE-2020-7488 A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. Ecostruxure_machine_expert, Modicon_m218_firmware, Modicon_m241_firmware, Modicon_m251_firmware, Modicon_m258_firmware, Somachine, Somachine_motion 7.5
2020-04-22 CVE-2020-7489 A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller. Ecostruxure_machine_expert, Modicon_m100_firmware, Modicon_m200_firmware, Modicon_m221_firmware, Somachine_basic 9.8
2021-05-26 CVE-2021-22705 Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert Ecostruxure_machine_expert, Vijeo_designer 7.8
2021-09-02 CVE-2021-22704 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. Ecostruxure_machine_expert, Vijeo_designer 9.1