Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Control_runtime_toolkit
(Codesys)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 5 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2019-08-15 | CVE-2019-9012 | An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000,... | Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_raspberry_pi_sl, Control_runtime_toolkit, Development_system, Gateway | 7.5 | ||
2019-02-19 | CVE-2018-20026 | Improper Communication Address Filtering exists in CODESYS V3 products versions prior V3.5.14.0. | Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_raspberry_pi_sl, Control_rte_sl, Control_rte_sl_\(For_beckhoff_cx\), Control_runtime_toolkit, Control_win_sl, Development_system_v3, Gateway, Hmi_sl, Opc_server, Plchandler, Safety_sil2, Targetvisu_sl | 7.5 | ||
2019-08-15 | CVE-2019-9010 | An issue was discovered in 3S-Smart CODESYS V3 products. The CODESYS Gateway does not correctly verify the ownership of a communication channel. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control... | Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_raspberry_pi_sl, Control_runtime_toolkit, Development_system, Gateway | 9.8 | ||
2019-01-29 | CVE-2018-10612 | In 3S-Smart Software Solutions GmbH CODESYS Control V3 products prior to version 3.5.14.0, user access management and communication encryption is not enabled by default, which could allow an attacker access to the device and sensitive information, including user credentials. | Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_raspberry_pi_sl, Control_rte_sl, Control_runtime_toolkit, Control_win_sl, Development_system_v3, Hmi_sl | 9.8 | ||
2019-02-19 | CVE-2018-20025 | Use of Insufficiently Random Values exists in CODESYS V3 products versions prior V3.5.14.0. | Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_raspberry_pi_sl, Control_rte_sl, Control_rte_sl_\(For_beckhoff_cx\), Control_runtime_toolkit, Control_win_sl, Development_system, Gateway, Hmi_sl, Safety_sil2 | 7.5 |