Product:

Compact_guardlogix_5380_firmware

(Rockwellautomation)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 5
Date Id Summary Products Score Patch Annotated
2022-04-01 CVE-2022-1159 Rockwell Automation Studio 5000 Logix Designer (all versions) are vulnerable when an attacker who achieves administrator access on a workstation running Studio 5000 Logix Designer could inject controller code undetectable to a user. Compact_guardlogix_5380_firmware, Compactlogix_5380_firmware, Compactlogix_5480_firmware, Controllogix_5580_firmware, Guardlogix_5580_firmware 7.2
2022-04-11 CVE-2022-1161 An attacker with the ability to modify a user program may change user program code on some ControlLogix, CompactLogix, and GuardLogix Control systems. Studio 5000 Logix Designer writes user-readable program code to a separate location than the executed compiled code, allowing an attacker to change one and not the other. Compact_guardlogix_5370_firmware, Compact_guardlogix_5380_firmware, Compactlogix_1768\-L43_firmware, Compactlogix_1768\-L45_firmware, Compactlogix_1769\-L31_firmware, Compactlogix_1769\-L32c_firmware, Compactlogix_1769\-L32e_firmware, Compactlogix_1769\-L35cr_firmware, Compactlogix_1769\-L35e_firmware, Compactlogix_5370_l1_firmware, Compactlogix_5370_l2_firmware, Compactlogix_5370_l3_firmware, Compactlogix_5380_firmware, Compactlogix_5480_firmware, Controllogix_5550_firmware, Controllogix_5560_firmware, Controllogix_5570_firmware, Controllogix_5580_firmware, Drivelogix_5730_firmware, Flexlogix_1794\-L34_firmware, Guardlogix_5560_firmware, Guardlogix_5570_firmware, Guardlogix_5580_firmware, Softlogix_5800_firmware 9.8
2022-06-02 CVE-2022-1797 A malformed Class 3 common industrial protocol message with a cached connection can cause a denial-of-service condition in Rockwell Automation Logix Controllers, resulting in a major nonrecoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online. Compact_guardlogix_5370_firmware, Compact_guardlogix_5380_firmware, Compactlogix_5370_firmware, Compactlogix_5380_firmware, Compactlogix_5480_firmware, Controllogix_5570_firmware, Controllogix_5580_firmware, Guardlogix_5570_firmware, Guardlogix_5580_firmware 8.6
2022-12-16 CVE-2022-3157 A vulnerability exists in the Rockwell Automation controllers that allows a malformed CIP request to cause a major non-recoverable fault (MNRF) and a denial-of-service condition (DOS). Compact_guardlogix_5370_firmware, Compact_guardlogix_5380_firmware, Compactlogix_5370_firmware, Controllogix_5570_firmware, Controllogix_5570_redundancy_firmware, Guardlogix_5570_firmware 7.5
2022-12-19 CVE-2022-3752 An unauthorized user could use a specially crafted sequence of Ethernet/IP messages, combined with heavy traffic loading to cause a denial-of-service condition in Rockwell Automation Logix controllers resulting in a major non-recoverable fault. If the target device becomes unavailable, a user would have to clear the fault and redownload the user project file to bring the device back online and continue normal operation. Compact_guardlogix_5380_firmware, Compactlogix_5380_firmware, Compactlogix_5480_firmware, Compactlogix_5580_firmware, Guardlogix_5580_firmware 7.5