Note:
This project will be discontinued after December 13, 2021. [more]
Product:
Gx_works3
(Mitsubishielectric)Repositories |
Unknown: This might be proprietary software. |
#Vulnerabilities | 33 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2021-02-19 | CVE-2021-20588 | Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000)... | C_controller_module_setting_and_monitoring_tool, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator, Fr_configurator2, Fr_configurator_sw3, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_configurator\-Dp, Gx_configurator\-Qp, Gx_developer, Gx_explorer, Gx_iec_developer, Gx_logviewer, Gx_remoteservice\-I, Gx_works2, Gx_works3, Iq_monozukuri_andon, Iq_monozukuri_process_remote_monitoring, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_em_software_development_kit, Melsoft_navigator, Mh11_settingtool_version2, Mi_configurator, Mt_works2, Mx_component, Network_interface_board_cc\-Link, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector | 9.8 | ||
2022-02-11 | CVE-2020-14523 | Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. | Cw_configurator, Fr_configurator2, Gx_works2, Gx_works3, Iu_configuration_tool, Iu_developer2, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Mr_configurator2, Mt_works2, Mx_component, Rd78g16_firmware, Rd78g32_firmware, Rd78g4_firmware, Rd78g64_firmware, Rd78g8_firmware, Rd78ghv_firmware, Rd78ghw_firmware, Rt_toolbox3 | 9.8 | ||
2022-02-11 | CVE-2020-14521 | Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. | C_controller_interface_module_utility, C_controller_module_setting_and_monitoring_tool, Cc\-Link_ie_control_network_data_collector, Cc\-Link_ie_field_network_data_collector, Cc\-Link_ie_tsn_data_collector, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator2, Fr_configurator_sw3, Gt_designer2_classic, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_developer, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_complete_clean_up_tool, Melsoft_em_software_development_kit, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Motorizer, Mr_configurator2, Mt_works2, Mtconnect_data_collector, Mx_component, Mx_mesinterface, Mx_mesinterface\-R, Mx_sheet, Network_interface_board_cc\-Link_ver\.2_utility_firmware, Network_interface_board_cc_ie_control_utility_firmware, Network_interface_board_cc_ie_field_utility_firmware, Network_interface_board_mneth_utility_firmware, Position_board_utility_2, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector | 9.8 | ||
2022-05-19 | CVE-2020-14496 | Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. | Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Em_configurator, Ezsocket, Fr_configurator2, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsoft_fielddeviceconfigurator, Melsoft_navigator, Mh11_settingtool_version2, Motorizer, Mr_configurator2, Mt_works2, Mx_component, Network_interface_board_cc\-Link_ver\.2_utility, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3 | 9.8 | ||
2022-11-25 | CVE-2022-25164 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.095Z and Mitsubishi Electric MX OPC UA Module Configurator-R versions 1.08J and prior allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers can gain unauthorized access to the MELSEC CPU module and the MELSEC OPC UA server module. | Gx_works3, Mx_opc_ua_module_configurator\-R | 7.5 | ||
2022-11-25 | CVE-2022-29825 | Use of Hard-coded Password vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U and GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C allows an unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. | Gx_works3 | 7.5 | ||
2022-11-25 | CVE-2022-29826 | Cleartext Storage of Sensitive Information vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.087R and Motion Control Setting(GX Works3 related software) versions from 1.000A to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. | Gx_works3 | 7.5 | ||
2022-11-25 | CVE-2022-29828 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project file or execute programs illegally. | Gx_works3 | 7.5 | ||
2022-11-25 | CVE-2022-29827 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A and later allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated attackers may view programs and project files or execute programs illegally. | Gx_works3 | 7.5 | ||
2022-11-25 | CVE-2022-29829 | Use of Hard-coded Cryptographic Key vulnerability in Mitsubishi Electric GX Works3 versions from 1.000A to 1.090U, GT Designer3 Version1 (GOT2000) versions from 1.122C to 1.290C and Motion Control Setting(GX Works3 related software) versions from 1.035M to 1.042U allows a remote unauthenticated attacker to disclose sensitive information. As a result, unauthenticated users may view programs and project files or execute programs illegally. | Gx_works3 | 7.5 |