#Vulnerabilities | 26 |
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2020-06-30 | CVE-2020-5602 | Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier, MELFA-Works Ver. 4.3 and earlier, MELSEC-L Flexible... | Cpu_module_logging_configuration_tool, Cw_configurator, Em_configurator, Gt_designer3, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec\-L_flexible_high\-Speed_i\/o_control_module_configuration_tool, Melsoft_fielddeviceconfigurator, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Mr_configurator2, Mt_works2, Rt_toolbox2, Rt_toolbox3 | 7.5 | ||
2020-06-30 | CVE-2020-5603 | Uncontrolled resource consumption vulnerability in Mitsubishi Electoric FA Engineering Software (CPU Module Logging Configuration Tool Ver. 1.94Y and earlier, CW Configurator Ver. 1.010L and earlier, EM Software Development Kit (EM Configurator) Ver. 1.010L and earlier, GT Designer3 (GOT2000) Ver. 1.221F and earlier, GX LogViewer Ver. 1.96A and earlier, GX Works2 Ver. 1.586L and earlier, GX Works3 Ver. 1.058L and earlier, M_CommDTM-HART Ver. 1.00A, M_CommDTM-IO-Link Ver. 1.02C and earlier,... | Cpu_module_logging_configuration_tool, Cw_configurator, Em_configurator, Gt_designer3, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec\-L_flexible_high\-Speed_i\/o_control_module_configuration_tool, Melsoft_fielddeviceconfigurator, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Mr_configurator2, Mt_works2, Rt_toolbox2, Rt_toolbox3 | 7.5 | ||
2021-02-19 | CVE-2021-20587 | Heap-based buffer overflow vulnerability in Mitsubishi Electric FA Engineering Software (CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000) versions 1.250L and prior, GT... | C_controller_module_setting_and_monitoring_tool, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator, Fr_configurator2, Fr_configurator_sw3, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_configurator\-Dp, Gx_configurator\-Qp, Gx_developer, Gx_explorer, Gx_iec_developer, Gx_logviewer, Gx_remoteservice\-I, Gx_works2, Gx_works3, Iq_monozukuri_andon, Iq_monozukuri_process_remote_monitoring, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_em_software_development_kit, Melsoft_navigator, Mh11_settingtool_version2, Mi_configurator, Mt_works2, Mx_component, Network_interface_board_cc\-Link, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector | 9.8 | ||
2021-02-19 | CVE-2021-20588 | Improper handling of length parameter inconsistency vulnerability in Mitsubishi Electric FA Engineering Software(CPU Module Logging Configuration Tool versions 1.112R and prior, CW Configurator versions 1.011M and prior, Data Transfer versions 3.44W and prior, EZSocket versions 5.4 and prior, FR Configurator all versions, FR Configurator SW3 all versions, FR Configurator2 versions 1.24A and prior, GT Designer3 Version1(GOT1000) versions 1.250L and prior, GT Designer3 Version1(GOT2000)... | C_controller_module_setting_and_monitoring_tool, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator, Fr_configurator2, Fr_configurator_sw3, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_configurator\-Dp, Gx_configurator\-Qp, Gx_developer, Gx_explorer, Gx_iec_developer, Gx_logviewer, Gx_remoteservice\-I, Gx_works2, Gx_works3, Iq_monozukuri_andon, Iq_monozukuri_process_remote_monitoring, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_em_software_development_kit, Melsoft_navigator, Mh11_settingtool_version2, Mi_configurator, Mt_works2, Mx_component, Network_interface_board_cc\-Link, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector | 9.8 | ||
2021-12-17 | CVE-2021-20607 | Integer Underflow vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. | Ezsocket, Gx_works2, Melsoft_navigator | 5.5 | ||
2021-12-17 | CVE-2021-20608 | Improper Handling of Length Parameter Inconsistency vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior allows a remote unauthenticated attacker to cause a DoS condition in GX Works2 by getting GX Works2 to read a tampered program file from a Mitsubishi Electric PLC by sending malicious crafted packets to tamper with the program file. | Gx_works2 | 7.5 | ||
2021-12-17 | CVE-2021-20606 | Out-of-bounds Read vulnerability in Mitsubishi Electric GX Works2 versions 1.606G and prior, Mitsubishi Electric MELSOFT Navigator versions 2.84N and prior and Mitsubishi Electric EZSocket versions 5.4 and prior allows an attacker to cause a DoS condition in the software by getting a user to open malicious project file specially crafted by an attacker. | Ezsocket, Gx_works2, Melsoft_navigator | 5.5 | ||
2022-02-11 | CVE-2020-14523 | Multiple Mitsubishi Electric Factory Automation products have a vulnerability that allows an attacker to execute arbitrary code. | Cw_configurator, Fr_configurator2, Gx_works2, Gx_works3, Iu_configuration_tool, Iu_developer2, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Mr_configurator2, Mt_works2, Mx_component, Rd78g16_firmware, Rd78g32_firmware, Rd78g4_firmware, Rd78g64_firmware, Rd78g8_firmware, Rd78ghv_firmware, Rd78ghw_firmware, Rt_toolbox3 | 9.8 | ||
2022-02-11 | CVE-2020-14521 | Multiple Mitsubishi Electric Factory Automation engineering software products have a malicious code execution vulnerability. A malicious attacker could use this vulnerability to obtain information, modify information, and cause a denial-of-service condition. | C_controller_interface_module_utility, C_controller_module_setting_and_monitoring_tool, Cc\-Link_ie_control_network_data_collector, Cc\-Link_ie_field_network_data_collector, Cc\-Link_ie_tsn_data_collector, Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Ezsocket, Fr_configurator2, Fr_configurator_sw3, Gt_designer2_classic, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_developer, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Io\-Link, Melfa\-Works, Melsec_wincpu_setting_utility, Melsoft_complete_clean_up_tool, Melsoft_em_software_development_kit, Melsoft_iq_appportal, Melsoft_navigator, Mi_configurator, Motion_control_setting, Motorizer, Mr_configurator2, Mt_works2, Mtconnect_data_collector, Mx_component, Mx_mesinterface, Mx_mesinterface\-R, Mx_sheet, Network_interface_board_cc\-Link_ver\.2_utility_firmware, Network_interface_board_cc_ie_control_utility_firmware, Network_interface_board_cc_ie_field_utility_firmware, Network_interface_board_mneth_utility_firmware, Position_board_utility_2, Px_developer, Rt_toolbox2, Rt_toolbox3, Setting\/monitoring_tools_for_the_c_controller_module, Slmp_data_collector | 9.8 | ||
2022-05-19 | CVE-2020-14496 | Successful exploitation of this vulnerability for multiple Mitsubishi Electric Factory Automation Engineering Software Products of various versions could allow an attacker to escalate privilege and execute malicious programs, which could cause a denial-of-service condition, and allow information to be disclosed, tampered with, and/or destroyed. | Cpu_module_logging_configuration_tool, Cw_configurator, Data_transfer, Em_configurator, Ezsocket, Fr_configurator2, Gt_designer3, Gt_softgot1000, Gt_softgot2000, Gx_logviewer, Gx_works2, Gx_works3, M_commdtm\-Hart, M_commdtm\-Io\-Link, Melfa\-Works, Melsoft_fielddeviceconfigurator, Melsoft_navigator, Mh11_settingtool_version2, Motorizer, Mr_configurator2, Mt_works2, Mx_component, Network_interface_board_cc\-Link_ver\.2_utility, Network_interface_board_cc_ie_control_utility, Network_interface_board_cc_ie_field_utility, Network_interface_board_mneth_utility, Px_developer, Rt_toolbox2, Rt_toolbox3 | 9.8 |