2023-08-03
|
CVE-2023-37558
|
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37559
|
Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_plcnext_sl, Control_for_raspberry_pi_sl, Control_for_wago_touch_panels_600_sl, Control_rte_sl, Control_rte_sl_\(For_beckhoff_cx\), Control_runtime_system_toolkit, Control_win_sl, Development_system, Hmi, Safety_sil2
|
N/A
|
|
|
2023-08-03
|
CVE-2023-37559
|
After successful authentication as a user in multiple Codesys products in multiple versions, specific crafted network communication requests with inconsistent content can cause the CmpAppForce component to read internally from an invalid address, potentially leading to a denial-of-service condition. This vulnerability is different to CVE-2023-37558
|
Control_for_beaglebone_sl, Control_for_empc\-A\/imx6_sl, Control_for_iot2000_sl, Control_for_linux_sl, Control_for_pfc100_sl, Control_for_pfc200_sl, Control_for_plcnext_sl, Control_for_raspberry_pi_sl, Control_for_wago_touch_panels_600_sl, Control_rte_sl, Control_rte_sl_\(For_beckhoff_cx\), Control_runtime_system_toolkit, Control_win_sl, Development_system, Hmi, Safety_sil2
|
N/A
|
|
|
2023-03-23
|
CVE-2018-25048
|
The CODESYS runtime system in multiple versions allows an remote low privileged attacker to use a path traversal vulnerability to access and modify all system files as well as DoS the device.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_pfc100, Control_for_pfc200, Control_for_raspberry_pi, Control_rte, Control_v3_runtime_system_toolkit, Control_win, Embedded_target_visu_toolkit, Hmi, Remote_target_visu_toolkit, Runtime_plcwinnt, Runtime_system_toolkit, Simulation_runtime
|
8.8
|
|
|
2019-09-17
|
CVE-2019-9008
|
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_pfc100, Control_for_pfc200, Control_for_raspberry_pi, Control_rte, Control_win, Hmi, Simulation_runtime
|
8.8
|
|
|
2019-09-17
|
CVE-2019-9009
|
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_pfc100, Control_for_pfc200, Control_for_raspberry_pi, Control_rte, Control_win, Gateway, Hmi, Linux, Runtime_system_toolkit, Safety_sil2, Simulation_runtime
|
7.5
|
|
|
2019-09-13
|
CVE-2019-13548
|
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_linux, Control_for_pfc100, Control_for_pfc200, Control_for_raspberry_pi, Control_rte, Control_runtime_system_toolkit, Control_win, Embedded_target_visu_toolkit, Hmi, Remote_target_visu_toolkit
|
9.8
|
|
|
2020-05-14
|
CVE-2020-12068
|
An issue was discovered in CODESYS Development System before 3.5.16.0. CODESYS WebVisu and CODESYS Remote TargetVisu are susceptible to privilege escalation.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_pfc100, Control_for_pfc200, Control_for_plcnext, Control_for_raspberry_pi, Control_rte, Control_runtime_system_toolkit, Control_win, Development_system, Hmi
|
6.5
|
|
|
2020-03-26
|
CVE-2020-10245
|
CODESYS V3 web server before 3.5.15.40, as used in CODESYS Control runtime systems, has a buffer overflow.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_linux, Control_for_pfc100, Control_for_pfc200, Control_for_plcnext, Control_for_raspberry_pi, Control_rte, Control_runtime_system_toolkit, Control_win, Embedded_target_visu_toolkit, Hmi, Remote_target_visu_toolkit
|
N/A
|
|
|
2019-11-20
|
CVE-2019-18858
|
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_linux, Control_for_pfc100, Control_for_pfc200, Control_for_plcnext, Control_for_raspberry_pi, Control_rte, Control_runtime_system_toolkit, Control_win, Embedded_target_visu_toolkit, Hmi, Remote_target_visu_toolkit
|
N/A
|
|
|
2019-09-13
|
CVE-2019-13532
|
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller.
|
Control_for_beaglebone, Control_for_empc\-A\/imx6, Control_for_iot2000, Control_for_linux, Control_for_pfc100, Control_for_pfc200, Control_for_raspberry_pi, Control_rte, Control_runtime_system_toolkit, Control_win, Embedded_target_visu_toolkit, Hmi, Remote_target_visu_toolkit
|
N/A
|
|
|