Date Id Summary Products Score Patch Annotated
2022-03-11 CVE-2022-21808 Path traversal vulnerability exists in CAMS for HIS Server contained in the following Yokogawa Electric products: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 8.8
2022-03-11 CVE-2022-22141 'Long-term Data Archive Package' service implemented in the following Yokogawa Electric products creates some named pipe with imporper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 7.8
2022-03-11 CVE-2022-22145 CAMS for HIS Log Server contained in the following Yokogawa Electric products is vulnerable to uncontrolled resource consumption. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 8.1
2022-03-11 CVE-2022-22148 'Root Service' service implemented in the following Yokogawa Electric products creates some named pipe with improper ACL configuration. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 7.8
2022-03-11 CVE-2022-22151 CAMS for HIS Log Server contained in the following Yokogawa Electric products fails to properly neutralize log outputs: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 8.1
2022-03-11 CVE-2022-22729 CAMS for HIS Server contained in the following Yokogawa Electric products improperly authenticate the receiving packets. The authentication may be bypassed via some crafted packets: CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, and Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 8.8
2022-03-11 CVE-2022-23401 The following Yokogawa Electric products contain insecure DLL loading issues. CENTUM CS 3000 versions from R3.08.10 to R3.09.00, CENTUM VP versions from R4.01.00 to R4.03.00, from R5.01.00 to R5.04.20, and from R6.01.00 to R6.08.00, Exaopc versions from R3.72.00 to R3.79.00. Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc 7.8
2020-02-05 CVE-2015-5628 Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless... B\/m9000_vp_firmware, B\/m9000cs_firmware, Centum_cs_1000_firmware, Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc, Exapilot, Exaplog, Exaquantum, Exaquantum\/batch, Exarqe, Exasmoc, Field_wireless_device_opc_server, Fieldmate, Plant_resource_manager, Prosafe\-Rs_firmware, Scada_software_\(Fast\/tools\), Stardom_opc_server, Versatile_data_server_software N/A
2020-02-05 CVE-2015-5627 Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless... B\/m9000_vp_firmware, B\/m9000cs_firmware, Centum_cs_1000_firmware, Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc, Exapilot, Exaplog, Exaquantum, Exaquantum\/batch, Exarqe, Exasmoc, Field_wireless_device_opc_server, Fieldmate, Plant_resource_manager, Prosafe\-Rs_firmware, Scada_software_\(Fast\/tools\), Stardom_opc_server, Versatile_data_server_software N/A
2020-02-05 CVE-2015-5626 Stack-based buffer overflow in Yokogawa CENTUM CS 1000 R3.08.70 and earlier, CENTUM CS 3000 R3.09.50 and earlier, CENTUM CS 3000 Entry R3.09.50 and earlier, CENTUM VP R5.04.20 and earlier, CENTUM VP Entry R5.04.20 and earlier, ProSafe-RS R3.02.10 and earlier, Exaopc R3.72.00 and earlier, Exaquantum R2.85.00 and earlier, Exaquantum/Batch R2.50.30 and earlier, Exapilot R3.96.10 and earlier, Exaplog R3.40.00 and earlier, Exasmoc R4.03.20 and earlier, Exarqe R4.03.20 and earlier, Field Wireless... B\/m9000_vp_firmware, B\/m9000cs_firmware, Centum_cs_1000_firmware, Centum_cs_3000_entry_firmware, Centum_cs_3000_firmware, Centum_vp_entry_firmware, Centum_vp_firmware, Exaopc, Exapilot, Exaplog, Exaquantum, Exaquantum\/batch, Exarqe, Exasmoc, Field_wireless_device_opc_server, Fieldmate, Plant_resource_manager, Prosafe\-Rs_firmware, Scada_software_\(Fast\/tools\), Stardom_opc_server, Versatile_data_server_software N/A