Date Id Summary Products Score Patch Annotated
2019-07-11 CVE-2019-10935 A vulnerability has been identified in SIMATIC PCS 7 V8.0 and earlier (All versions), SIMATIC PCS 7 V8.1 (All versions < V8.1 with WinCC V7.3 Upd 19), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1 with WinCC V7.4 SP1 Upd 11), SIMATIC PCS 7 V9.0 (All versions < V9.0 SP2 with WinCC V7.4 SP1 Upd11), SIMATIC WinCC Professional (TIA Portal V13) (All versions), SIMATIC WinCC Professional (TIA Portal V14) (All versions < V14 SP1 Upd 9), SIMATIC WinCC Professional (TIA Portal V15) (All versions <... Simatic_pcs_7, Simatic_wincc, Simatic_wincc_runtime 7.2
2018-12-13 CVE-2018-13814 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V14), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V14), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V14), SIMATIC WinCC Runtime Advanced (All versions < V14), SIMATIC WinCC Runtime Professional (All versions < V14), SIMATIC WinCC (TIA Portal) (All versions < V14), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). The... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 8.8
2018-12-13 CVE-2018-13813 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 8.1
2018-12-13 CVE-2018-13812 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15 Update 4), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15 Update 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15 Update 4), SIMATIC WinCC Runtime Advanced (All versions < V15 Update 4), SIMATIC WinCC Runtime Professional (All versions < V15 Update 4), SIMATIC WinCC (TIA Portal) (All versions < V15 Update 4), SIMATIC HMI Classic... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 7.5
2019-05-14 CVE-2019-6577 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 5.4
2019-05-14 CVE-2019-6576 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 7.5
2019-05-14 CVE-2019-6572 A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI... Simatic_hmi_comfort_outdoor_panels_firmware, Simatic_hmi_comfort_panels_firmware, Simatic_hmi_ktp_mobile_panels_ktp400f_firmware, Simatic_hmi_ktp_mobile_panels_ktp700_firmware, Simatic_hmi_ktp_mobile_panels_ktp700f_firmware, Simatic_hmi_ktp_mobile_panels_ktp900_firmware, Simatic_hmi_ktp_mobile_panels_ktp900f_firmware, Simatic_hmi_mp_firmware, Simatic_hmi_op_firmware, Simatic_hmi_tp_firmware, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 9.1
2017-05-11 CVE-2017-6867 A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Simatic_wincc, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime 4.9
2016-11-15 CVE-2016-7165 A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic,... Primary_setup_tool, Security_configuration_tool, Simatic_it_production_suite, Simatic_net_pc_software, Simatic_pcs7, Simatic_pcs_7, Simatic_step_7, Simatic_step_7_\(Tia_portal\), Simatic_winac_rtx_2010, Simatic_winac_rtx_f_2010, Simatic_wincc, Simatic_wincc_\(Tia_portal\), Simatic_wincc_runtime, Simit, Sinema_remote_connect, Sinema_server, Softnet_security_client, Telecontrol_basic 6.4
2011-09-16 CVE-2011-3321 Heap-based buffer overflow in the Siemens WinCC Runtime Advanced Loader, as used in SIMATIC WinCC flexible Runtime and SIMATIC WinCC (TIA Portal) Runtime Advanced, allows remote attackers to cause a denial of service (memory corruption) or possibly execute arbitrary code via a crafted packet to TCP port 2308. Simatic_wincc_flexible_runtime, Simatic_wincc_runtime N/A