Date Id Summary Products Score Patch Annotated
2019-05-22 CVE-2018-7852 A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when an invalid private command parameter is sent to the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7844 A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading memory blocks from the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7853 A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause denial of service when reading invalid physical memory blocks in the controller over Modbus Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7854 A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a denial of Service when sending invalid debug parameters to the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7855 A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7856 A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of Service when writing invalid memory blocks to the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2018-7857 A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible Denial of Service when writing out of bounds variables to the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2019-6806 A CWE-200: Information Exposure vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause the disclosure of SNMP information when reading variables in the controller using Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2019-6807 A CWE-248: Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a possible denial of service when writing sensitive application variables to the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 7.5
2019-05-22 CVE-2019-6808 A CWE-284: Improper Access Control vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a remote code execution by overwriting configuration settings of the controller over Modbus. Modicon_m340_firmware, Modicon_m580_firmware, Modicon_premium_firmware, Modicon_quantum_firmware 9.8