Product:

Ecostruxure_control_expert

(Schneider\-Electric)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 25
Date Id Summary Products Score Patch Annotated
2020-11-19 CVE-2020-28213 A CWE-494: Download of Code Without Integrity Check vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause unauthorized command execution when sending specially crafted requests over Modbus. Ecostruxure_control_expert 8.8
2020-11-19 CVE-2020-7538 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. Ecostruxure_control_expert 7.5
2020-11-19 CVE-2020-7559 A CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability exists in PLC Simulator on EcoStruxureª Control Expert (now Unity Pro) (all versions) that could cause a crash of the PLC simulator present in EcoStruxureª Control Expert software when receiving a specially crafted request over Modbus. Ecostruxure_control_expert 7.5
2020-12-11 CVE-2020-7560 A CWE-123: Write-what-where Condition vulnerability exists in EcoStruxure™ Control Expert (all versions) and Unity Pro (former name of EcoStruxure™ Control Expert) (all versions), that could cause a crash of the software or unexpected code execution when opening a malicious file in EcoStruxure™ Control Expert software. Ecostruxure_control_expert, Unity_pro 8.6
2021-07-14 CVE-2021-22778 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause protected derived function blocks to be read or modified by unauthorized users when accessing a project file. Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 7.1
2021-07-14 CVE-2021-22779 Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in... Ecostruxure_control_expert, Ecostruxure_process_expert, Modicon_m340_bmxp341000_firmware, Modicon_m340_bmxp342010_firmware, Modicon_m340_bmxp342020_firmware, Modicon_m340_bmxp342030_firmware, Modicon_m580_bmeh582040_firmware, Modicon_m580_bmeh582040c_firmware, Modicon_m580_bmeh582040s_firmware, Modicon_m580_bmeh584040_firmware, Modicon_m580_bmeh584040c_firmware, Modicon_m580_bmeh584040s_firmware, Modicon_m580_bmeh586040_firmware, Modicon_m580_bmeh586040c_firmware, Modicon_m580_bmeh586040s_firmware, Modicon_m580_bmep581020_firmware, Modicon_m580_bmep581020h_firmware, Modicon_m580_bmep582020_firmware, Modicon_m580_bmep582020h_firmware, Modicon_m580_bmep582040_firmware, Modicon_m580_bmep582040h_firmware, Modicon_m580_bmep582040s_firmware, Modicon_m580_bmep583020_firmware, Modicon_m580_bmep583040_firmware, Modicon_m580_bmep584020_firmware, Modicon_m580_bmep584040_firmware, Modicon_m580_bmep584040s_firmware, Modicon_m580_bmep585040_firmware, Modicon_m580_bmep585040c_firmware, Modicon_m580_bmep586040_firmware, Modicon_m580_bmep586040c_firmware, Remoteconnect 9.1
2021-07-14 CVE-2021-22780 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to... Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 7.1
2021-07-14 CVE-2021-22781 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 5.5
2021-07-14 CVE-2021-22782 Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file. Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 5.5
2022-03-09 CVE-2022-24322 A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior) Ecostruxure_control_expert 5.9