Product:

Ecostruxure_control_expert

(Schneider\-Electric)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 25
Date Id Summary Products Score Patch Annotated
2021-07-14 CVE-2021-22779 Authentication Bypass by Spoofing vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Control Expert V15.0 SP1, EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), SCADAPack RemoteConnect for x70 (all versions), Modicon M580 CPU (all versions - part numbers BMEP* and BMEH*), Modicon M340 CPU (all versions - part numbers BMXP34*), that could cause unauthorized access in... Ecostruxure_control_expert, Ecostruxure_process_expert, Modicon_m340_bmxp341000_firmware, Modicon_m340_bmxp342010_firmware, Modicon_m340_bmxp342020_firmware, Modicon_m340_bmxp342030_firmware, Modicon_m580_bmeh582040_firmware, Modicon_m580_bmeh582040c_firmware, Modicon_m580_bmeh582040s_firmware, Modicon_m580_bmeh584040_firmware, Modicon_m580_bmeh584040c_firmware, Modicon_m580_bmeh584040s_firmware, Modicon_m580_bmeh586040_firmware, Modicon_m580_bmeh586040c_firmware, Modicon_m580_bmeh586040s_firmware, Modicon_m580_bmep581020_firmware, Modicon_m580_bmep581020h_firmware, Modicon_m580_bmep582020_firmware, Modicon_m580_bmep582020h_firmware, Modicon_m580_bmep582040_firmware, Modicon_m580_bmep582040h_firmware, Modicon_m580_bmep582040s_firmware, Modicon_m580_bmep583020_firmware, Modicon_m580_bmep583040_firmware, Modicon_m580_bmep584020_firmware, Modicon_m580_bmep584040_firmware, Modicon_m580_bmep584040s_firmware, Modicon_m580_bmep585040_firmware, Modicon_m580_bmep585040c_firmware, Modicon_m580_bmep586040_firmware, Modicon_m580_bmep586040c_firmware, Remoteconnect 9.1
2021-07-14 CVE-2021-22780 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause unauthorized access to a project file protected by a password when this file is shared with untrusted sources. An attacker may bypass the password protection and be able to... Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 7.1
2021-07-14 CVE-2021-22781 Insufficiently Protected Credentials vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause a leak of SMTP credential used for mailbox authentication when an attacker can access a project file. Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 5.5
2021-07-14 CVE-2021-22782 Missing Encryption of Sensitive Data vulnerability exists in EcoStruxure Control Expert (all versions prior to V15.0 SP1, including all versions of Unity Pro), EcoStruxure Process Expert (all versions, including all versions of EcoStruxure Hybrid DCS), and SCADAPack RemoteConnect for x70, all versions, that could cause an information leak allowing disclosure of network and process information, credentials or intellectual property when an attacker can access a project file. Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 5.5
2022-03-09 CVE-2022-24322 A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior) Ecostruxure_control_expert 5.9
2022-03-09 CVE-2022-24323 A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause a disruption of communication between the Modicon controller and the engineering software, when an attacker is able to intercept and manipulate specific Modbus response data. Affected Product: EcoStruxure Process Expert (V2021 and prior), EcoStruxure Control Expert (V15.0 SP1 and prior) Ecostruxure_control_expert, Ecostruxure_process_expert 5.9
2022-04-13 CVE-2021-22797 A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal) vulnerability exists that could cause malicious script to be deployed in an unauthorized location and may result in code execution on the engineering workstation when a malicious project file is loaded in the engineering software. Affected Product: EcoStruxure Control Expert (V15.0 SP1 and prior, including former Unity Pro), EcoStruxure Process Expert (2020 and prior, including former HDCS), SCADAPack... Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 7.8
2022-04-14 CVE-2022-26507 A heap-based buffer overflow exists in XML Decompression DecodeTreeBlock in AT&T Labs Xmill 0.7. A crafted input file can lead to remote code execution. This is not the same as any of: CVE-2021-21810, CVE-2021-21811, CVE-2021-21812, CVE-2021-21815, CVE-2021-21825, CVE-2021-21826, CVE-2021-21828, CVE-2021-21829, or CVE-2021-21830. NOTE: This vulnerability only affects products that are no longer supported by the maintainer Xmill, Ecostruxure_control_expert, Ecostruxure_process_expert, Remoteconnect 9.8
2022-09-12 CVE-2022-37300 A CWE-640: Weak Password Recovery Mechanism for Forgotten Password vulnerability exists that could cause unauthorized access in read and write mode to the controller when communicating over Modbus. Affected Products: EcoStruxure Control Expert Including all Unity Pro versions (former name of EcoStruxure Control Expert) (V15.0 SP1 and prior), EcoStruxure Process Expert, Including all versions of EcoStruxure Hybrid DCS (former name of EcoStruxure Process Expert) (V2021 and prior), Modicon M340... Ecostruxure_control_expert, Ecostruxure_process_expert, Modicon_m340_bmxp341000_firmware, Modicon_m340_bmxp342000_firmware, Modicon_m340_bmxp3420102_firmware, Modicon_m340_bmxp342010_firmware, Modicon_m340_bmxp342020_firmware, Modicon_m340_bmxp342020h_firmware, Modicon_m340_bmxp3420302_firmware, Modicon_m340_bmxp3420302h_firmware, Modicon_m340_bmxp342030_firmware, Modicon_m340_bmxp342030h_firmware, Modicon_m580_bmeh582040_firmware, Modicon_m580_bmeh582040c_firmware, Modicon_m580_bmeh582040s_firmware, Modicon_m580_bmeh584040_firmware, Modicon_m580_bmeh584040c_firmware, Modicon_m580_bmeh584040s_firmware, Modicon_m580_bmeh586040_firmware, Modicon_m580_bmeh586040c_firmware, Modicon_m580_bmeh586040s_firmware, Modicon_m580_bmep581020_firmware, Modicon_m580_bmep581020h_firmware, Modicon_m580_bmep582020_firmware, Modicon_m580_bmep582020h_firmware, Modicon_m580_bmep582040_firmware, Modicon_m580_bmep582040h_firmware, Modicon_m580_bmep583020_firmware, Modicon_m580_bmep583040_firmware, Modicon_m580_bmep584020_firmware, Modicon_m580_bmep584040_firmware, Modicon_m580_bmep584040s_firmware, Modicon_m580_bmep585040_firmware, Modicon_m580_bmep585040c_firmware, Modicon_m580_bmep586040_firmware, Modicon_m580_bmep586040c_firmware 9.8
2022-09-13 CVE-2022-37302 A CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause a crash of the Control Expert software when an incorrect project file is opened. Affected Products: EcoStruxure Control Expert(V15.1 HF001 and prior). Ecostruxure_control_expert 5.5