Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2021-07-09 | CVE-2021-33012 | Rockwell Automation MicroLogix 1100, all versions, allows a remote, unauthenticated attacker sending specially crafted commands to cause the PLC to fault when the controller is switched to RUN mode, which results in a denial-of-service condition. If successfully exploited, this vulnerability will cause the controller to fault whenever the controller is switched to RUN mode. | Micrologix_1100_firmware | 8.6 | ||
2022-07-20 | CVE-2022-2179 | The X-Frame-Options header in Rockwell Automation MicroLogix 1100/1400 Versions 21.007 and prior is not configured in the HTTP response, which could allow clickjacking attacks. | Micrologix_1100_firmware, Micrologix_1400_firmware | 6.5 | ||
2022-12-16 | CVE-2022-3166 | Rockwell Automation was made aware that the webservers of the Micrologix 1100 and 1400 controllers contain a vulnerability that may lead to a denial-of-service condition. The security vulnerability could be exploited by an attacker with network access to the affected systems by sending TCP packets to webserver and closing it abruptly which would cause a denial-of-service condition for the web server application on the device | Micrologix_1100_firmware, Micrologix_1400_firmware | 7.5 | ||
2022-12-16 | CVE-2022-46670 | Rockwell Automation was made aware of a vulnerability by a security researcher from Georgia Institute of Technology that the MicroLogix 1100 and 1400 controllers contain a vulnerability that may give an attacker the ability to accomplish remote code execution. The vulnerability is an unauthenticated stored cross-site scripting vulnerability in the embedded webserver. The payload is transferred to the controller over SNMP and is rendered on the homepage of the embedded website. | Micrologix_1100_firmware, Micrologix_1400\-A_firmware, Micrologix_1400\-B_firmware, Micrologix_1400\-C_firmware, Micrologix_1400_firmware | 6.1 | ||
2019-04-25 | CVE-2019-10955 | In Rockwell Automation MicroLogix 1400 Controllers Series A, All Versions Series B, v15.002 and earlier, MicroLogix 1100 Controllers v14.00 and earlier, CompactLogix 5370 L1 controllers v30.014 and earlier, CompactLogix 5370 L2 controllers v30.014 and earlier, CompactLogix 5370 L3 controllers (includes CompactLogix GuardLogix controllers) v30.014 and earlier, an open redirect vulnerability could allow a remote unauthenticated attacker to input a malicious link to redirect users to a... | Compactlogix_5370_l1_firmware, Compactlogix_5370_l2_firmware, Compactlogix_5370_l3_firmware, Micrologix_1100_firmware, Micrologix_1400_a_firmware, Micrologix_1400_b_firmware | 6.1 | ||
2015-10-28 | CVE-2015-6492 | Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote attackers to cause a denial of service (memory corruption and device crash) via a crafted HTTP request. | Micrologix_1100_firmware, Micrologix_1400_firmware | N/A | ||
2015-10-28 | CVE-2015-6491 | Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allow remote authenticated users to insert the content of an arbitrary file into a FRAME element via unspecified vectors. | Micrologix_1100_firmware, Micrologix_1400_firmware | N/A | ||
2015-10-28 | CVE-2015-6490 | Stack-based buffer overflow on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices through B FRN 15.003 allows remote attackers to execute arbitrary code via unspecified vectors. | Micrologix_1100_firmware, Micrologix_1400_firmware | N/A | ||
2015-10-28 | CVE-2015-6488 | Cross-site scripting (XSS) vulnerability in the web server on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote attackers to inject arbitrary web script or HTML via unspecified vectors. | Micrologix_1100_firmware, Micrologix_1400_firmware | N/A | ||
2015-10-28 | CVE-2015-6486 | SQL injection vulnerability on Allen-Bradley MicroLogix 1100 devices before B FRN 15.000 and 1400 devices before B FRN 15.003 allows remote authenticated users to execute arbitrary SQL commands via unspecified vectors. | Micrologix_1100_firmware, Micrologix_1400_firmware | N/A |