Product:

Junos

(Juniper)
Date Id Summary Products Score Patch Annotated
2019-10-09 CVE-2019-0060 The flowd process, responsible for forwarding traffic in SRX Series services gateways, may crash and restart when processing specific transit IP packets through an IPSec tunnel. Continued processing of these packets may result in an extended Denial of Service (DoS) condition. This issue only occurs when IPSec tunnels are configured. Systems without IPSec tunnel configurations are not vulnerable to this issue. This issue affects Juniper Networks Junos OS: 15.1X49 versions prior to... Junos 7.5
2019-10-09 CVE-2019-0061 The management daemon (MGD) is responsible for all configuration and management operations in Junos OS. The Junos CLI communicates with MGD over an internal unix-domain socket and is granted special permission to open this protected mode socket. Due to a misconfiguration of the internal socket, a local, authenticated user may be able to exploit this vulnerability to gain administrative privileges. This issue only affects Linux-based platforms. FreeBSD-based platforms are unaffected by this... Junos 7.8
2019-10-09 CVE-2019-0051 SSL-Proxy feature on SRX devices fails to handle a hardware resource limitation which can be exploited by remote SSL/TLS servers to crash the flowd daemon. Repeated crashes of the flowd daemon can result in an extended denial of service condition. For this issue to occur, clients protected by the SRX device must initiate a connection to the malicious server. This issue affects: Juniper Networks Junos OS on SRX5000 Series: 12.3X48 versions prior to 12.3X48-D85; 15.1X49 versions prior to... Junos 7.5
2019-10-09 CVE-2019-0047 A persistent Cross-Site Scripting (XSS) vulnerability in Junos OS J-Web interface may allow remote unauthenticated attackers to perform administrative actions on the Junos device. Successful exploitation requires a Junos administrator to first perform certain diagnostic actions on J-Web. This issue affects: Juniper Networks Junos OS 12.1X46 versions prior to 12.1X46-D86; 12.3 versions prior to 12.3R12-S13; 12.3X48 versions prior to 12.3X48-D80; 14.1X53 versions prior to 14.1X53-D51; 15.1... Junos 8.8
2019-04-10 CVE-2019-0036 When configuring a stateless firewall filter in Junos OS, terms named using the format "internal-n" (e.g. "internal-1", "internal-2", etc.) are silently ignored. No warning is issued during configuration, and the config is committed without error, but the filter criteria will match all packets leading to unexpected results. Affected releases are Juniper Networks Junos OS: All versions prior to and including 12.3; 14.1X53 versions prior to 14.1X53-D130, 14.1X53-D49; 15.1 versions prior to... Junos 9.8
2019-04-10 CVE-2019-0035 When "set system ports console insecure" is enabled, root login is disallowed for Junos OS as expected. However, the root password can be changed using "set system root-authentication plain-text-password" on systems booted from an OAM (Operations, Administration, and Maintenance) volume, leading to a possible administrative bypass with physical access to the console. OAM volumes (e.g. flash drives) are typically instantiated as /dev/gpt/oam, or /oam for short. Password recovery, changing the... Junos 6.8
2019-01-15 CVE-2019-0002 On EX2300 and EX3400 series, stateless firewall filter configuration that uses the action 'policer' in combination with other actions might not take effect. When this issue occurs, the output of the command: show pfe filter hw summary will not show the entry for: RACL group Affected releases are Junos OS on EX2300 and EX3400 series: 15.1X53 versions prior to 15.1X53-D590; 18.1 versions prior to 18.1R3; 18.2 versions prior to 18.2R2. This issue affect both IPv4 and IPv6 firewall filter. Junos 9.8
2018-01-10 CVE-2018-0007 An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to the local segment, through a local segment broadcast, may be able to cause a Junos device to enter an improper boundary check condition allowing a memory corruption to occur, leading to a denial of service. Further crafted packets may be able to sustain the denial of service condition. Score: 6.5 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) Further, if the attacker is authenticated on the... Junos 9.8
2019-01-15 CVE-2019-0014 On QFX and PTX Series, receipt of a malformed packet for J-Flow sampling might crash the FPC (Flexible PIC Concentrator) process which causes all interfaces to go down. By continuously sending the offending packet, an attacker can repeatedly crash the FPC process causing a sustained Denial of Service (DoS). This issue affects both IPv4 and IPv6 packet processing. Affected releases are Juniper Networks Junos OS on QFX and PTX Series: 17.4 versions prior to 17.4R2-S1, 17.4R3; 18.1 versions... Junos 7.5
2020-02-28 CVE-2015-3006 On the QFX3500 and QFX3600 platforms, the number of bytes collected from the RANDOM_INTERRUPT entropy source when the device boots up is insufficient, possibly leading to weak or duplicate SSH keys or self-signed SSL/TLS certificates. Entropy increases after the system has been up and running for some time, but immediately after boot, the entropy is very low. This issue only affects the QFX3500 and QFX3600 switches. No other Juniper Networks products or platforms are affected by this weak... Junos N/A