Product:

Diaenergie

(Deltaww)
Repositories

Unknown:

This might be proprietary software.

#Vulnerabilities 63
Date Id Summary Products Score Patch Annotated
2021-12-22 CVE-2021-31558 DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “descr” of the script “DIAE_hierarchyHandler.ashx”. Diaenergie 6.1
2021-12-22 CVE-2021-44544 DIAEnergie Version 1.7.5 and prior is vulnerable to multiple cross-site scripting vulnerabilities when arbitrary code is injected into the parameter “name” of the script “HandlerEnergyType.ashx”. Diaenergie 6.1
2021-12-22 CVE-2021-44471 DIAEnergie Version 1.7.5 and prior is vulnerable to stored cross-site scripting when an unauthenticated user injects arbitrary code into the parameter “name” of the script “DIAE_HandlerAlarmGroup.ashx”. Diaenergie 6.1
2021-08-30 CVE-2021-38390 A Blind SQL injection vulnerability exists in the /DataHandler/HandlerEnergyType.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter egyid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER. Diaenergie 9.8
2021-08-30 CVE-2021-32983 A Blind SQL injection vulnerability exists in the /DataHandler/Handler_CFG.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter keyword before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER. Diaenergie 9.8
2021-08-30 CVE-2021-38391 A Blind SQL injection vulnerability exists in the /DataHandler/AM/AM_Handler.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter type before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER. Diaenergie 9.8
2021-08-30 CVE-2021-38393 A Blind SQL injection vulnerability exists in the /DataHandler/HandlerAlarmGroup.ashx endpoint of Delta Electronics DIAEnergie Version 1.7.5 and prior. The application does not properly validate the user-controlled value supplied through the parameter agid before using it as part of an SQL query. A remote, unauthenticated attacker can exploit this issue to execute arbitrary code in the context of NT SERVICE\MSSQLSERVER. Diaenergie 9.8
2021-08-30 CVE-2021-33003 Delta Electronics DIAEnergie Version 1.7.5 and prior may allow an attacker to retrieve passwords in cleartext due to a weak hashing algorithm. Diaenergie 5.5
2021-08-30 CVE-2021-32955 Delta Electronics DIAEnergie Version 1.7.5 and prior allows unrestricted file uploads, which may allow an attacker to remotely execute code. Diaenergie 9.8
2021-08-30 CVE-2021-32991 Delta Electronics DIAEnergie Version 1.7.5 and prior is vulnerable to cross-site request forgery, which may allow an attacker to cause a user to carry out an action unintentionally. Diaenergie 4.3