Note:
This project will be discontinued after December 13, 2021. [more]
Main entries ~3681 :
Remaining NVD entries (unprocessed / no code available): ~263562 :
Date | Id | Summary | Products | Score | Patch | Annotated |
---|---|---|---|---|---|---|
2014-03-01 | CVE-2014-1912 | Buffer overflow in the socket.recvfrom_into function in Modules/socketmodule.c in Python 2.5 before 2.7.7, 3.x before 3.3.4, and 3.4.x before 3.4rc1 allows remote attackers to execute arbitrary code via a crafted string. | Mac_os_x, Python | N/A | ||
2014-04-07 | CVE-2014-0160 | Heartbleed - The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. | Symantec_messaging_gateway, Ubuntu_linux, Debian_linux, Fedora, Filezilla_server, V100_firmware, V60_firmware, Micollab, Mivoice, Openssl, Opensuse, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation, Gluster_storage, Storage, Virtualization, S9922l_firmware, Application_processing_engine_firmware, Cp_1543\-1_firmware, Elan\-8\.2, Simatic_s7\-1500_firmware, Simatic_s7\-1500t_firmware, Wincc_open_architecture, Splunk | 7.5 | ||
2021-09-08 | CVE-2021-40346 | An integer overflow exists in HAProxy 2.0 through 2.5 in htx_add_header that can be exploited to perform an HTTP request smuggling attack, allowing an attacker to bypass all configured http-request HAProxy ACLs and possibly other ACLs. | Haproxy, Haproxy_docker_image | 7.5 | ||
2016-06-08 | CVE-2016-5108 | Buffer overflow in the DecodeAdpcmImaQT function in modules/codec/adpcm.c in VideoLAN VLC media player before 2.2.4 allows remote attackers to cause a denial of service (crash) or possibly execute arbitrary code via a crafted QuickTime IMA file. | Debian_linux, Vlc_media_player | 9.8 | ||
2017-06-01 | CVE-2017-8386 | git-shell did not correctly validate the given project path, allowing an argument injection which leads to arbitrary file reads and in some configurations command execution. | Ubuntu_linux, Debian_linux, Fedora, Git\-Shell, Leap | 8.8 | ||
2018-04-06 | CVE-2018-1000156 | GNU patch is processd by ed. This allows arbitrary command executions through a line beginning with ! | Ubuntu_linux, Debian_linux, Patch, Enterprise_linux_desktop, Enterprise_linux_server, Enterprise_linux_server_aus, Enterprise_linux_server_eus, Enterprise_linux_server_tus, Enterprise_linux_workstation | 7.8 | ||
2018-06-08 | CVE-2018-4222 | There is an out-of-bounds read when compiling WebAssembly source buffers in WebKit. If the buffer is a view, the offset is added to the buffer twice before this is copied. This could allow memory off the heap to be read out of the source buffer, either though parsing exceptions or data sections when they are copied | Icloud, Iphone_os, Itunes, Safari, Tvos, Watchos, Ubuntu_linux | 8.8 |
Date | Id | Summary | Products | Score | Patch |
---|---|---|---|---|---|
2024-07-09 | CVE-2024-3596 | RADIUS Protocol under RFC 2865 is susceptible to forgery attacks by a local attacker who can modify any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response using a chosen-prefix collision attack against MD5 Response Authenticator signature. | N/A | N/A | |
2024-07-09 | CVE-2022-45147 | A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions), SIMATIC STEP 7 V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter... | N/A | N/A | |
2024-07-09 | CVE-2023-32735 | A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified... | N/A | N/A | |
2024-07-09 | CVE-2023-32737 | A vulnerability has been identified in SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing user-controllable input. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. | N/A | N/A | |
2024-07-09 | CVE-2023-52237 | A vulnerability has been identified in RUGGEDCOM i800, RUGGEDCOM i800NC, RUGGEDCOM i801, RUGGEDCOM i801NC, RUGGEDCOM i802, RUGGEDCOM i802NC, RUGGEDCOM i803, RUGGEDCOM i803NC, RUGGEDCOM M2100, RUGGEDCOM M2100NC, RUGGEDCOM M2200, RUGGEDCOM M2200NC, RUGGEDCOM M969, RUGGEDCOM M969NC, RUGGEDCOM RMC30, RUGGEDCOM RMC30NC, RUGGEDCOM RMC8388 V4.X, RUGGEDCOM RMC8388 V5.X, RUGGEDCOM RMC8388NC V4.X, RUGGEDCOM RMC8388NC V5.X, RUGGEDCOM RP110, RUGGEDCOM RP110NC, RUGGEDCOM RS1600, RUGGEDCOM RS1600F,... | N/A | N/A | |
2024-07-09 | CVE-2023-52238 | A vulnerability has been identified in RUGGEDCOM RST2228 (All versions < V5.9.0), RUGGEDCOM RST2228P (All versions < V5.9.0). The web server of the affected systems leaks the MACSEC key in clear text to a logged in user. An attacker with the credentials of a low privileged user could retrieve the MACSEC key and access (decrypt) the ethernet frames sent by authorized recipients. | N/A | N/A | |
2024-07-09 | CVE-2023-52891 | A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.5), SIMATIC Energy Manager PRO (All versions < V7.5), SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions), SIMIT V10 (All versions), SIMIT V11 (All versions < V11.1). Unified Automation .NET based OPC UA Server SDK before 3.2.2 used in Siemens products are affected by a similar vulnerability as documented in CVE-2023-27321 for the OPC Foundation UA .NET Standard implementation. A... | N/A | N/A |